|
Coolant
The coolant type is displayed in multiple
places thoughout the system, where appropriate.
Click the adjacent button to display the User
Defined Coolant dialog. Select the required coolant(s) for the
current procedure.
Coolant dialog displayed from the parameter grid: |
Coolant dialog displayed from the Cutters & Holders dialog: |
|
The Use Coolant checkbox defines whether coolants should be exported from the Cutters & Holders table to the procedure's parameter grid. When this checkbox is OFF
|
The coolant types and pressure values displayed in the dialog are defined in the NC Preferences (for each coolant type that is checked ON in the preference and given a coolant name).
The coolant displayed in the parameter grid or elsewhere in the system, depends on the selection in the User Defined Coolant dialog, above.
If no coolant if defined, Coolant OFF is displayed.
If one coolant is defined, the coolant name is displayed.
If multiple coolants are defined, Multi is displayed.
For multiple cutters, you can set a different coolant for each cutter. In this case, the Coolant button displays See Cutters; clicking this opens the Cutters & Holders branch of the parameter grid, where the Coolant for each cutter may be defined.
Note:
If a discrepancy exists between the values in the Preference and the coolant value saved in a procedure, the
flag is displayed in the Process Manager (for example:
). This may occur if the Preference values are changed or if a template with different settings is loaded.
The indication remains until the Coolant button is pressed or until the discrepancy is solved.
|