NC Preferences > Drill > Group Naming
Access: Invoke this function from one of the following locations:
-
Select the Preferences button
from the Quick Access Toolbar, or
-
Select Tools > Main Tools > Preferences from the menu bar.
Navigate to NC > Drill > Group Naming.
Define the default naming convention for groups in the Automated Drill procedure. The names assigned to groups of holes can either be user or system-defined.
Groups of holes in the Automated Drill procedure are automatically named based on the geometry of the holes and their manufacturing attributes.
A group name may contain the following elements:
Prefix, separator, Diameter sign, Diameter, separator, Attribute, separator, Blind/Through, separator, Sequential.
Some of these elements may be empty. The separator only separates between non-empty components.
|
|
|
|
Group Naming Method: |
|
Group Naming Method: |
User-defined example group name elements |
If more than one attribute exists, the name is defined using the following priority:
Thread – the thread name is used. For example "M12", "3/8 -24 UNF".
Manufacturing Technique (use the string).
Coded (the value is used: H6, etc.).
Diameter tolerance, other than "coded" (the text defined in the Preference is used).
Exact Position (the text defined in the Preference is used).
Depth Tolerance (the text defined in the Preference is used).
The Group Naming dialog is displayed.
Interaction
Define the default group naming convention.
Group Naming Method |
Set the naming method from the following dropdown list - see the examples below of the results of the different options:
|
||||||||
Prefix for group with Single |
The prefix depends if the number of straight segments in a hole is one (single) or more (multi). Set the prefix for a group of a single segment, with or without an attribute. |
||||||||
With Attribute |
The attribute is used as the prefix. |
||||||||
Without Attribute |
Prefix for a group of a single segment without an attribute. Default = Drill. |
||||||||
Prefix for group with Multi |
The prefix depends if the number of straight segments in a hole is one (single) or more (multi). Set the prefix for a group of multiple segments, with or without attributes. |
||||||||
With Attribute |
Prefix for a group of multiple segments with attributes. Default = Multi. |
||||||||
Without Attribute |
Prefix for a group of multiple segments without attributes. Default = Multi. |
||||||||
Diameter sign |
Set the default diameter sign. Default =D. |
||||||||
Diameter Tolerance sign |
Set the default diameter tolerance sign. Default = D-Tol. |
||||||||
Depth Tolerance sign |
Set the default depth tolerance sign. Default = H-Tol. |
||||||||
Exact Position sign |
Set the default exact position sign. Default = Ex. |
||||||||
Through Hole Sign |
Set the default through hole sign. |
||||||||
Blind Hole Sign |
Set the default blind hole sign. |
||||||||
Sequential |
Set the sequential hole naming from the following dropdown list:
|
||||||||
Diameter comes from |
Set from which element the hole diameter is defined, from the following dropdown list:
|
||||||||
Separator |
Set the default separator sign.
|
||||||||
Undefined Groups Name |
This is a global name for groups that cannot be defined for any reason, for example: by points, by pocket, no straight segment, etc.
|
Press the appropriate approval option.
|