Gouge checking is not performed on closed contours.
Up to 3000 contours may be defined.
START/END CHECK CURVE are relevant to the first or last curve only.
If a conic cutter is used, the draft angle is automatically defined as equal to the taper angle of the cutter. It is not possible to change the draft angle by hand.
For best results, it is recommended to use TRIM LOOPS: GLOBAL. If it is important to obtain fast results, use TRIM LOOPS: LOCAL.
|